Test Mode
Information for NOKIA TDMA models
Nokia
51XX/61XX/71XX, 3285, 63XX, Etc. (except GSM)
1.
Turn on the phone. Press * 3 0 0 1 # 1 2 3 4 5 #
2.
Scroll up to where it says “Field Test” and choose SELECT
3.
Highlight “enable” and choose OK. Turn the phone off then back on
again.
4.
If the test mode does not show up press MENU and scroll down to
“Field Test” choose SELECT. Press 0 1 then choose OK.
5.
Lower left or upper left number is the signal strength.
6.
To turn off the test mode press MENU and scroll down to where it says
“Field Test” choose SELECT. Press 0 0 and then choose OK.
Nokia 3360, 6360
1.
Turn on the phone. Press * 3 0 0 1 # 1 2 3 4 5 #
2.
Scroll up to where it says “Field Test” and choose SELECT
3.
Highlight “Enable” and choose OK. Then the phone off then back on
again.
4.
If the test mode screen does not show up press MENU and scroll down
to “Field Test” choose SELECT. Press 2 1 0 1 then choose OK.
5.
Lower left or upper left number is the signal strength.
6.
To turn off the test mode press MENU and scroll down to where it says
“Field Test” choose SELECT Press 2 1 0 0 and then choose OK.
If 2100 doesn't work try 3101.
TYPICAL SCREENS (MAY BE DIFFERENT)
Screen 1
Digital control channel
| Rssi DVC S |
| Bchan Pw A |
| CS-state |
|
Digital traffic channel
| Rssi DVC S |
| Bchan l Be |
| CS-state |
|
Analog control channel
| Rssi D d |
| Bchan Pw A |
| CS-state |
|
Analog traffic channel
| Rssi s d |
| Bchan l a
|
| CS-state |
|
|
Rssi Received Signal Strength Indicator (-113 to
-51 dBm, increments in steps of 2 dB)
DVC Digital Verification Colour Code (1-255 or --- for not
locked)
D Digital Verification Colour Code in analog control channel (0-3
or - for not locked)
s SAT Colour (0-2)
d Data Receiving Status (0 = no data, 1 = unable to read, 2 =
read and correcting, 3 = read and not correcting)
S Time slot (1-3)
B Network Band and Frequency (lowercase a,b = 800 MHz band;
uppercase A,B,C,D,E,F = 1900 MHz band)
chan Channel (0001-1999)
Be Bit Error Ratio
Pw Maximum Access Power on control channel (DCCH: 0-10 or - for
not locked; ACCH: 0-7 or - for not locked)
l Transmit level (0-10 or - for OFF)
A Authentication status (0 = disabled, 1 = enabled, - = not
locked)
a Audio State (0 = OFF or 1 = ON)
CS-state Indication of Cellular State as follows:
DCCH: SCAN-LOCK - Scanning and locking of Digital Control Channel
DCCH: DCCH-SEL - DCCH selectionb
DCCH: CAMPING - Channel camping
DCCH: REGISTR - Registration
DCCH: WAIT-ORDER - Waiting for order
DCCH: ORIGINAT - Origination proceeding
DCCH: RESELECT - Reselection
DCCH: ORIG-SMS - Origination SMS proceeding
DCCH: TERM-SMS - Termination of SMS
DTCH: TCH - Confirming traffic channel
XTCH: CONVERSAT - Conversation
ACCH: OOR - Out Of Range
ACCH: SCAN-PDCH - Scan primary dedicated control channels
ACCH: SCAN-SDCH - Scan secondary dedicated control channels
ACCH: SCAN-PCH - Scan paging channels
ACCH: IDLE - Idle
ACCH: ACCESS - Access
ACCH: VCH - Confirm Voice Channel
|
Screen 2
Digital control channel
| Mode M C |
| FB E SP pc |
| net SID.. |
|
Digital traffic channel
| Mode DTX |
| ENCR CIPH |
| d a TA S |
| CODEC... |
|
Analog control channel
Analog traffic channel
|
Mode One of: DCCH, DTCH, ACCH, or AVCH
XSTBY Shown when extended standby is active SID System
Identification Number 0-32767
SAT SAT validity (0-32767)
DTX text DTX is shown when DTX is on
ENCR Shown when message encryption is active
CIPH Shown when voice ciphering is active
d Data receiving status (0 = not active, 1 = active)
a Audio state (0 = OFF, 1 = ON)
TA Current time alignment (0-30)
S Service code (1 = digital speech, 1 = async data call, 2 = G3
FAX call)
CODEC CODEC in use
M Maximum paging frame class supported by network (1-8)
C Current paging frame class (1-8)
FB Number of F-BCCH slots
E Number of E-BCCH slots
SP Number of SPACH slots
pc PCH subchannel
net Supported network types (0 = not supported, 1 = supported; in
order of one char each: public, private, residential)
|
Screen 3
| RS SS SI b |
| NA ND |
| MA MD MO |
|
|
RS Minimum Received Signal Strength required to
access cell (0 to 31)
SS Minimum Signal Strength for reselection
SI Scan Interval between consecutive strength measurements in
hyperframes (1 to 16)
b Access burst sieze (0 for normal, 1 for abbreviated RACH)
NA Number of analog neighbours (0 to 24)
ND Number of digital neighbours (0 to 24)
MA Number of analog neighbours in multihyperband (0 to 24)
MD Number of digital neighbours in multihyperband (0 to 24)
MO Number of neighbours in other band (0 to 24)
|
Screen 4
| SID ##### t |
| NN NT NR |
| Alphatag.. |
|
|
SID System Identification Number (0 to 32767,
odd for 'A' carriers, even for 'B' carriers)
t Network type where registered (- = none, 0 = ACCH, 1 =
residential, 2 = private, 4 = public)
NN Number of PSIDs/RSIDs in NAM area
NT Number of PSIDs/RSIDs in Test Registration area
NR Number of PSIDs/RSIDs in Registration Accept area
Alphatag User display (not present on all models) |
Screen 5
| S bandorde |
| NC NP IRC |
| RSCO RSLO |
|
|
S Current band in use (a, b, A, B, C, D, E, F,
or -)
bandorde Network search order: (a - 800 MHz A-band; b - 800 MHz
B-band; A - 900 MHz A-band; B - 1900 MHz B-band; C - 1900 MHz C-band; D
- 1900 MHz D-band; E - 1900 MHz E-band; F- 1900 MHz F-band)
NC Number of AMPS probability blocks to scan (0 to 16)
NP Number of PCS probability blocks to scan (0 to 7)
IRC IR Control (0 or 1)
RSCO Rescan Count. Time in hyperframes (1.28 sec each) how long
to wait before searching for acceptable SP on the last used accectable
band
RSLO Rescan Loop. Tells how many times to search the last used
acceptable band before doing a wide band scan |
Screen 6
|
|
PSC Number of Partner SOCs (0 to 82)
PSD Number of Partner SIDs (0 to 82)
FSC Number of Favoured SOCs (0 to 82)
FSD Number of Favoured SIDs (0 to 82)
XSC Number of Forbidden SOCs (0 to 82)
XSD Number of Forbidden SIDs (0 to 82) |
Screen 7
|